Ultrasound Applications - Doppler
Flow Phantoms
The Model
U-245 tissue equivalent Doppler flow phantom is
for the evaluation of diagnostic Doppler ultrasound.
Carotid Anthropomorphic Vascular Phantoms (SEA Series)
- These Doppler phantoms are fabricated with thin walled carotid bifurcation
vessels embedded in an agarose/gelatine tissue mimic and encased in an
air tight acrylic box with an acoustic window. This product line of geometrically
characterized carotid bifurcation phantoms (normal and various stenoses
options) offers the added benefit of being compatible with ultrasound,
MRI and radiographic imaging modalities making them ideal for multi-modality
comparisons. Link to PubMed publication: Click
Here Carotid Bifurcation Models geometrically characterized and embedded in
agar
QATP Doppler flow phantom product line
was designed for the assessment of clinical Doppler ultrasound devices.
Three models are available to offer the end user the option of agarose
(gelatine), urethane or Zerdine™ tissue mimicking materials. These
three models possess the same dimensional and geometric configurations,
as follows: QATP Phantom Dimensions
QATP Phantom Vessel Geometry
Each phantom contains two vessels with known vessel geometry. An 8 mm
diameter horizontal vessels enables evaluation of velocity and flow measurements.
Doppler sensitivity is assessed in a 4 mm diameter vessel on a 45º
angle. Tissue equivalent material model options are as follows: QATP- 100/A Model The two vessels are embedded in an agarose/gelatine
tissue mimicking material. • Speed of sound 1540 m/s ± 10 m/s at 22ºC • Attenuation coefficient 0.7 dB/cm/MHz @ 5 MHz QATP - 100/U Model The two vessels are embedded in a urethane
tissue mimicking material. • Speed of sound 1430 m/s ± 10 m/s at 20ºC • Attenuation coefficient 0.5 dB/cm/MHz ± 0.05 dB/cm/MHz
@ 5 MHz QATP - 100/Z Model The two vessels are embedded in a Zerdine™
tissue mimicking material. • Speed of sound 1540 m/s ± 6 m/s at 22ºC • Attenuation coefficient 0.5 dB/cm/MHz or 0.7 dB/cm/MHz The SMI Doppler flow phantom product line was designed used for
the assessment of clinical Doppler ultrasound devices. Three models are
available, all using agarose (gelatine) as the tissue mimicking material.
These phantoms will be of interest to manufacturers of clinical Doppler
ultrasound devices. SMI 100 Model Two parallel vessels with 4.8 mm and 7.9 mm inner
diameters embedded in agarose/gelatine. C70-ASEA Model Two vessels with inner diameters of 4.8 mm and
0.8 mm, one vessel is parallel to the surface, the other is angulated
at 40 degrees embedded in agarose/gelatine. C70-ASEA Model Three vessels with inner diameters of 3.175 mm,
one vessel is parallel to the surface, one is angulated at 25.2 degrees,
the other at 31.0 degrees embedded in agarose/gelatine. A custom vasculature and vessel phantom design and fabrication service is also available. |
|||||||||||||||||||||||||||||||||||||